Industrieausrüstung /  Andere Industrieausrüstung /  Industrielle und Wissenschaftliche Messausrüstung / 
Informationen über den produzenten
Firma:
Guangzhou Amittari Instruments Co., Ltd.
 
Adresse:
42, Huannan East Street, Huanhua Rd., Liwan District
 
Telefon:
+86-20-81523500

.

SPECIFICATIONSDisplay: 4 digits, 10 mm LCD, with blue backlightParameters:  Ra, Rz, Rq, RtMeasuring Range      Ra: 0.005-10.00um/1.000-400.0uinch     Rq:  0.005-16.00um/0.020-629.9uinch     Rz:  0.020-100.0um/0.780-4000uinch     Rt: 0.020-160.0um/0.780-6299uinchAccuracy: ≤±10%Fluctuation of display value: Not more than 6%Sensor :          Test Principle: Inductance type         Radius of Probe Pin: 10um         Material of Probe Pin: Diamond         Dynamo-measurement of Probe: 4mN(0.4gf)         Probe Angle: 90°         Vertical Radius of Guiding Head: 48mmMaximum driving stroke:  17.5mm/0.7inchCutoff length (l): 0.25mm / 0.8mm / 2.5mm  optionalEvaluation length:  5lDriving speed:          sampling length = 0.25mm   Vt=0.135mm/s         sampling length = 0.8mm    Vt=0.5mm/s         sampling length = 2.5mm    Vt=1mm/s         returning                                Vt=1mm/sProfile digital filter         Filtered Profile:            RC         Filtered Profile:            PC-RC         Filtered Profile:            Gauss         Non-Filtered Profile:        D-PResolution : 0.001μm    if reading
In den WarenkorbIn den Warenkorb Internetauftritt des HerstellersInternetauftritt des Herstellers




Andere Waren dieses Produzenten :
 ()
SPECIFICATIONSDisplay: 4 digits, 18 mm LCD         Measured values and makers          (units, 10,and  battery symbol)Transducer : Piezoelec
 ()
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution:   0.1 H (A,D)Measurement deviation:  error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
 ()
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution:   0.1 H (A,D)Measurement deviation:  error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
 ()
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution:   0.1 H (A,D)Measurement deviation:  error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
 ()
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution:   0.1 H (A,D)Measurement deviation:  error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
 ()
Technical SpecificationsDisplay: 12.5mm LCD with back light Accuracy: Display error ±0.8% at HLD=900Measuring range: 200-900HLD Conversion: HLD-HRC-HRB-HB-HV-HSD Materials: 9 dif
 ()
SPECIFICATIONSDisplay:4 digits,LCDRange: 0 um to 750 um               (0 mils to 29.5 mils)Accuracy: ±5% or ±5 µm,       &n
 ()
SPECIFICATIONSDisplay:4 digits,LCDRange: 0 um to 750 um               (0 mils to 29.5 mils)Accuracy: ±5% or ±5 µm,       &n
 ()
SPECIFICATIONSDisplay: 4 digits, 10 mm LCD, with blue backlightParameters:  Ra, Rz, Rq, RtMeasuring Range      Ra, Rq:  0.005-16.00um/0.020-629.9uinch     

Òàê æå â êàòåãîðèè "Industrielle und Wissenschaftliche Messausrüstung":
CORE COMPETENCY
CORE COMPE...
Triggering Oscilloscope
Triggering...
Patient Monitor, Model: USCARE2000
Patient Mo...
3-Phase Voltage Relay
3-Phase Vo...
MT Series Transmitter
MT Series ...
FREE TRANSMITTER TOOLING
FREE TRANS...
 