SPECIFICATIONSDisplay: 4 digits, 18 mm LCD Measured values and makers (units, 10,and battery symbol)Transducer : Piezoelectric accelerometerParameters measured:Velocity, Acceleration, Displacement, RPM and Frequency Measuring range : Velocity : 0.1-400 m/s2 true RMS Acceleration : 0.1-400.0m/s equivalent peak Displacement : 0.001-4.000mm equivalent pk-pkFrequency: 1-10 kHzFrequency range for measuringAcceleration : 10Hz. to 1kHz. In '1' mode 10Hz. to 10kHz. In '10' mode for bearing condition checkVelocity : 10Hz. to 1kHz.Displacement : 10Hz. to 1kHz. Accuracy: ± 5%+2 digitsMetric/ Imperial conversionPC interface: RS232COutput: AC output 2.0V peak full scale (load resistance: above 10k)Power supply: 4x1.5 AAA size (UM-4) batteriesPower off : 2 modes, Manual off at any time Operating conditions: Temperature : 0~50 °C, Humidity : below 90% RHSize: 148x63x28mm Weigh: 190g(not include batteries) Accessories included : 1. Powerful rare earth magnet 1 pc.2. Accelerometer 1 pc.3. Stinger probe (Cone) 1 pc.4. Stinger probe (Ball) 1 pc.5. Carrying case 1 pc.6. Operation manual 1 pc.Optional accessories: Headphones for use as electronic stethoscope Cable and software for RS232C
|
|
 |
Andere Waren dieses Produzenten : |
 |
|
|
|
|
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution: 0.1 H (A,D)Measurement deviation: error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
|
| |
|
|
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution: 0.1 H (A,D)Measurement deviation: error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
|
| |
|
|
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution: 0.1 H (A,D)Measurement deviation: error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
|
|
|
|
|
SPECIFICATIONSDisplay: 4 digits, 10 mm LCDRange: 10~90 H(A, D)Resolution: 0.1 H (A,D)Measurement deviation: error≤ ±1 Power supply: 2x1.5v AAA (UM-4) batteryOperating condi
|
| |
|
|
Technical SpecificationsDisplay: 12.5mm LCD with back light Accuracy: Display error ±0.8% at HLD=900Measuring range: 200-900HLD Conversion: HLD-HRC-HRB-HB-HV-HSD Materials: 9 dif
|
| |
|
|
SPECIFICATIONSDisplay:4 digits,LCDRange: 0 um to 750 um (0 mils to 29.5 mils)Accuracy: ±5% or ±5 µm, &n
|
|
|
|
|
SPECIFICATIONSDisplay:4 digits,LCDRange: 0 um to 750 um (0 mils to 29.5 mils)Accuracy: ±5% or ±5 µm, &n
|
| |
|
|
SPECIFICATIONSDisplay: 4 digits, 10 mm LCD, with blue backlightParameters: Ra, Rz, Rq, RtMeasuring Range Ra, Rq: 0.005-16.00um/0.020-629.9uinch
|
| |
|
|
Ultrasonic thickness gauge1 Portable thickness gauge2 Easy Calibration3 Can connect with PC4 CE approved, can OEM
|
|
|
|