Closed center Center open to pressure Center open to exhaust Closed center Center open to pressure Center open to exhaust Model code Drip-Proof type MVPCF-03-E3K MVPEF-03-E3K MVPOF-03-E3K MVPCN-08-E3K MVPEN-08-E3K MVPON-08-E3K Explosion-Proof type Pressure-resistant packing system MVPCF-03-E2K MVPEF-03-E2K MVPOF-03-E2K MVPCN-08-E2K MVPEN-08-E2K MVPON-08-E2K Metal conduit system MVPCF-03-E1K MVPEF-03-E1K MVPOF-03-E1K MVPCN-08-E1K MVPEN-08-E1K MVPON-08-E1K Structure of the main valve Pilot-acting spool valve Port size Rc1/4・Rc3/8・Rc1/2 Rc3/4・Rc 1 Effective area of valve 40mm2(2.2)・55mm2(3.0)・70mm2(3.8) 175mm2(9.5)・185mm2(10.0) Working pressure 0.2~0.7MPa 0.12~0.7MPa Ambient temp. -5~60℃ -20~50℃ Explosion-proof standard d2G4
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensiv
Return Kind of barrier to combine ExiaⅡBT5 SAF3-5 414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi 416S303M-YAi 416S603M-YAi 416S604M-YAi In the
Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy t
Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy t
Employing poppet structure for both main valve and pilot valve, this product has achieved optimal resistance to drains and dusts. Incorporated exhaust pressure protection system ensures reliable opera