Address: Huayangnian,huahaoyuan community,Jitou Town, Wuhou District
Phone: +86-28-85218395
Konan Intrinsic Safety Solenoid Valves 414/416 series 5-port solenoid valves Ter
Return Kind of barrier to combine ExiaⅡBT5 SAF3-5 414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi 416S303M-YAi 416S603M-YAi 416S604M-YAi In the case of other explosion-proof barriers and combination *1 Structure of the main valve Pilot spool type Pilot ceramic slide type Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2 Working pressure 0.2~0.7MPa 0.12~0.7MPa Ambient temp. -5~50℃ -10~60℃ Explosion-proof standard Intrinsic safety construction Operating condition 1. Use with specified safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 2. Parts and connections cannot be changed. 3. Use 1 explosion-proof barrier for each solenoid valve. note *1 In the case of other barriers and combination Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve. The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.) The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions. Safety retention voltage Maximum voltage of a intrinsic safety circuit Less than 29.4V Maximum current of a intrinsic safety circuit Less than 93.8mA Electric power of a intrinsic safety circuit Less than 0.689W Performance classification / Group Performance classification ia Group ⅡB or ⅡC Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH) Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF)
Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy t
Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy t
Employing poppet structure for both main valve and pilot valve, this product has achieved optimal resistance to drains and dusts. Incorporated exhaust pressure protection system ensures reliable opera
Suitable for single-acting actuators and diaphragm valves. Two types (NC, NO) are available. The valve incorporates plastic cassette valve, low power consumption solenoid, and DIN connector Compact in
Sub-plate type solenoid valve focusing safety in operation and easy maintenance. Employing sizes complying with ISO and JIS standards, this valve is suitable for multiple applications With standardize
Direct piping type 5-port solenoid valve that is a mainstay of Magster III series. With basic concepts of compact size, large flow, and low power consumption, this high-performance valve has been deve