Russian German French    |    help
   Add to favorite    Favorite products
   
Description
Medical & Pharmaceuticals /  Medical Equipment /  Other Medical Equipment / 
Producer information
Company:
General Meditech Inc.
 
Address:
4/F, South Office Building, 1 Kezhi West Road, Technology Park, Nanshan, Shenzhen, Guangdong, China (Mainland) Zip: 518057 &
 
Phone:
+86-755-26500832

Veterinary Patient Monitor


Features:1) Multi-language operating interface selection: English, Spanish, Portuguese,France, Arabic, and Chinese2) Rechargeable high-energy built-in battery3) Accurately measure the SpO2 in low perfusion situation4) Low-power design with standby mode and no-fan type5) Against electro surgical-interference and electric-knife; defibrillated6) Three-application mode: monitoring, diagnosis, operating7) Networking function with central monitoring system and software upgrade possible8) History data storage up to 360 hours9) Audio and visual comprehensive alarm10) applications in hospital like emergency pre-and post-operative care,theater/operating room, intermediate care/step down units, labor and delivery,hospital-based special procedure areas and outdoor ambulance surgery11) Suitable for adult, pediatrics, neonatesStandard configuration: ECG, HR, PR, SpO2, Oxy CRG diagram, ST analysis, RESP*, NIBP(with venous punch), TEMP, drug dose calculationOptional configuration: wireless connection, built-in printer, ETCO2 and 2-IBPTechnical parameters:1) Temperature (surface and rectal)a) Measurement range: 25 - 45 centigradeb) Accuracy: -1% ~1% centigradec) Resolution: 0.1 centigraded) Response time: less than 3 min.2) ECGInput: 5 wires ECG cableLead section: I, II, III/ aVR, aVL, aVF/ V, MCL1Gain (mm/mV): 1/4, 1/2, 1, 2, 4Frequency response:a) Diagnosis 0.05 - 100Hzb) Monitor: 0.5 - 40Hzc) Surgery: 1.0 - 25HzSweep speed (mm/sec): 12.5, 25, 50Heart rate range: 30-254 BPMHeart rate accuracy: ±1 %ST segment deviation analysis: -0.8~0.8mVST accuracy: ±0.02mV3) Respiration rate (RA-LL impedance and nasal cavity)a) Measurement range: 0 - 120 BPM(adult)b) Accuracy: -1~1 BPM or 5 %c) Resolution: 1 BPM4) Pulse oximeterSPO2 measurement range: 0 - 100 %; resolution: 1 %Pulse measurement range: 30- 254BPM;accuracy: -2%~2%;resolution: 1 BPM5) Non-invasive blood pressure:Measurement type: adult, pediatric, neonatalMeasurement range:a) Systolic: 4.0 - 37.0kPab) Diastolic: 1.3 - 33.0kPac) Mean: 2.6 - 35.0kPaAccuracy: ±0.4kPa or 5 %; resolution: 0.1kPaProtection: over pressure6) ETCO2 (side stream type)Measurement range: 0 % - 10.0 % (ins CO2 and et CO2)Accuracy: -2~2 mmHg (less than 5% measurement value);10% (>5% measurement value)Response time: 180ms

Add to BasketAdd to Basket Web addressWeb address



Other goods of this manufacturer :
Veterinary Patient Monitor
 Veterinary Patient Monitor ( Veterinary Patient Monitor)
Features:1) Multi-language operating interface selection: English, Spanish, Portuguese,France, Arabic, and Chinese2) Rechargeable high-energy built-in battery3) Accurately measure the SpO2 in low perf
Handheld Pulse Oximeter
 Handheld Pulse Oximeter ( Handheld Pulse Oximeter)
Product Name: Handheld Pulse OximeterModel Number: G1B-VETPlace of Origin: ChinaFeatures:1) SpO2:Measurement range: 0-100%Accuracy: 2% ~ +2% during 70% - 100%, -3% ~ +3% during 60% - 69%2) Pulse rate:
Handheld Pulse Oximeter
 Handheld Pulse Oximeter ( Handheld Pulse Oximeter)
Product Name: Handheld Pulse OximeterModel Number: G1BPlace of Origin: China1. Digital technology2. Alarm set possible3. Accurate measurement during low perfusion4. Anti-movement, stable performance5.
Handheld Pulse Oximeter
 Handheld Pulse Oximeter ( Handheld Pulse Oximeter)
Product Name: Handheld Pulse OximeterModel Number: G1BPlace of Origin: ChinaFeatures:1) SpO2:a) Measurement range: 0-100%b) Accuracy: ±2% during 70%-100%; ±3% during 60%-69%2) Pulse rate:a)
Handheld Pulse Oximeter
 Handheld Pulse Oximeter ( Handheld Pulse Oximeter)
Features:1) SpO2:a) Measurement range: 0-100%b) Accuracy: ±2% during 70%-100%; ±3% during 60%-69%2) Pulse rate:a) Measurement range: 30bpm-250bpm%b) Accuracy: 1bpm or ±2%3) Visual displ
Handheld Pulse Oximeter G1B
 Handheld Pulse Oximeter G1B ( Handheld Pulse Oximeter G1B)
Features:1) SpO2:a) Measurement range: 0-100%b) Accuracy: ±2% during 70%-100%; ±3% during 60%-69%2) Pulse rate:a) Measurement range: 30bpm-250bpm%b) Accuracy: 1bpm or ±2%3) Visual displ
Patient Monitor
 Patient Monitor ( Patient Monitor)
Product Name: Patient MonitorModel Number: G3CPlace of Origin: ChinaFeatures:1) Multi-language operating interface selection: English, Spanish, Portuguese,France, Arabic, and Chinese2) Rechargeable hi
Patient Monitor
 Patient Monitor ( Patient Monitor)
Product Name: Patient MonitorModel Number: G3A Patient MonitorPlace of Origin: ChinaFeatures:1) Multi-language Operating interface selection: English, Spanish, Portuguese,France, Arabic, and Chinese2)
Patient Monitor G3A
 Patient Monitor G3A ( Patient Monitor G3A)
Features:1) Multi-language Operating interface selection: English, Spanish, Portuguese, France, Arabic, and Chinese2) Rechargeable high-energy built-in battery3) Accurately measure the SpO2 in low per

Likewise in category "Other Medical Equipment":
Alcohol Tester, Alcohol Breath Tester
Alcohol Te...
DISPOSABLE MEDICAL COMPONENTS
DISPOSABLE...
Ceramic Kevlar Scissors
Ceramic Ke...
ADULT DIAPERExposure-Proof Sheet
ADULT DIAP...
Duplicating Gel
Duplicatin...
Task chair
Task chair
 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com