Description |
|
|
|
|
|
Producer information
Company: Baoguang Group Co., Ltd. |
|
Address: Taishang Industrial Zone, Huanghua Town, Yueqing, Zhejiang, China (Mainland) Zip: 325605 |
|
Phone: +86-577-61723375 |
|
Ceramic Vacuum Interrupter
Main technique parameters:1) Rated voltage: 1.14kV2) Rated current: 250A3) Rated put through current: 2,500A4) Rated breaking current: 2,000A5) Limiting breaking current: 2,500A6) Rated short-time withstand current: 2,500A7) Mechanical life: 1,000,000 times8) Rated breaking time:a) AC3 type: 150,000 timesb) AC4 type: 6,000 times9) Contact automatic blocking ability: 50±10N, 50±20N10) Force required to hold contacts open at full stroke: 70±10N,70±20N11) The resistance under contact automatic blocking ability loop:≤120µΩ12) Contact-wear allowance thickness: 2mm13) Storage period: 20 yearsTechnical specifications of the contactor:1) Clearance between open contacts: 2±0.2mm2) Contact travel: 1±0.2mm3) Average closing speed: 0.6±0.1m/s, 0.6±0.2N4) Average opening speed: 0.3±0.1m/s5) Rated contact pressure: 100±20N, 80±20N6) Contact closing bounce time: ≤2ms7) Contact opening/closing non-synchrony: ≤2ms
Add to Basket
Web address
|
|
|
Other goods of this manufacturer : |
|
|
|
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 1.14kV2) Rated current: 125/400A3) Rated frequency: 50Hz4) Rated put through current: 1,250/4,000A5) Rated breaking current: 1,000/3,200A6) Limiting breakin
|
| |
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 1.14kV2) Rated current: 630A3) Rated frequency: 50Hz4) Rated put through current: 6,000 / 6,300A5) Rated breaking current: 4,800 / 5,040A6) Limiting breakin
|
| |
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 40.5kV2) Rated current: 1,600A3) Rated short-circuit breaking current: 25kA4) Rated short-circuit making current: 63kA5) Rated peak withstand current: 63kA6
|
|
|
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 12kV2) Rated current: 1,250A3) Rated short-circuit breaking current: 20/25kA4) Rated short-circuit making current: 50/63kA5) Rated peak withstand current: 5
|
| |
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 7.2kV2) Rated current: 630A3) Rated frequency: 50Hz4) Rated put through current: 6,300A5) Rated breaking current: 5,040A6) Limiting breaking current: 6,300A
|
| |
Ceramic Vacuum Interrupter
|
|
Main technique parameters:1) Rated voltage: 12kV2) Rated current: 2,500A3) Rated short-circuit breaking current: 40kA4) Rated short-circuit making current: 100kA5) Rated peak withstand current: 100kA6
|
|
|
Ceramic Vacuum Interrupter
|
|
Product Name: Ceramic Vacuum InterrupterModel Number: BGE506, BGE516Place of Origin: ChinaMain technique parameters:1) Rated voltage: 1.14kV2) Rated current: 250A3) Rated put through current: 2,500A4)
|
| |
Ceramic Vacuum Interrupter
|
|
Product Name: Ceramic Vacuum InterrupterModel Number: BGE630, BGE632Place of Origin: ChinaMain technique parameters:1) Rated voltage: 40.5kV2) Rated current: 1,600A3) Rated short-circuit breaking curr
|
| |
Ceramic Vacuum Interrupter
|
|
Product Name: Ceramic Vacuum InterrupterModel Number: BGE617Place of Origin: ChinaMain technique parameters:1) Rated voltage: 12kV2) Rated current: 2,500A3) Rated short-circuit breaking current: 40kA4
|
|
|
|
Likewise in category "Jumpers, Switchers": |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|