Address: Lutoushi Village,Xiangyang Town, Yueqing, Zhejiang, China (Mainland) Zip: 325619
Phone: +86-577-62602220
Composite Suspension/Tension Insulator
Features:1) Manufactured by means of injection whole-molding technology2) The juncture between end fitting and core is totally embedded in HTV silicone rubber, eliminating conventional and traditional seal defectsMaterials:1) Silicon Rubber for sheds/ housing2) Glass-fiber reinforced epoxy resin rod (ECR type) for core3) Hop dip galvanized cast steel for metal fittingsElectromechanical specifications:Type:FXBW2-24/70UD1) Rated voltage:24KV2) Rated mechanical load:70KN3) Height:430mm4) Insulating distance:290mm5) Min. Nominal creepage distance:680mm6) 1 min power frequency wet withstand voltage:42KV7) Full wave lighting impulse withstand voltage(peak value):150KVType:FXB2-24/70UD1) Rated voltage:24KV2) Rated mechanical load:70KN3) Height:430mm4) Insulating distance:290mm5) Min. Nominal creepage distance:680mm6) 1 min power frequency wet withstand voltage:42KV7) Full wave lighting impulse withstand voltage(peak value):150KVType:FXB2-33/70UD1) Rated voltage:33KV2) Rated mechanical load:70KN3) Height:550mm4) Insulating distance:360mm5) Min. Nominal creepage distance:720mm6) 1min power frequency wet withstand voltage:95KV7) Full wave lighting impulse withstand voltage(peak value):230KVType:FXB2-35/70UD1) Rated voltage:35KV2) Rated mechanical load:70KN3) Height:570mm4) Insulating distance:400mm5) Min. Nominal creepage distance:1000mm6) 1 min power frequency wet withstand voltage:95KV7) Full wave lighting impulse withstand voltage(peak value):230KVType:FXB2-15/70UD1)Rated voltage:15KV2) Rated mechanical load:70KN3) Height:375mm4) Insulating distance:200mm5) Min. Nominal creepage distance:470mm6) 1 min power frequency wet withstand voltage:42KV7) Full wave lighting impulse withstand voltage(peak value):105KV
Designation of type lettersF(1)(2)-(3)(4)(5)1 F: Safety protective covers2 (1): Terminal category (T-transformer, B-surge arrester)3 (2): Voltage class (10-10KV, 1-1KV)4 (3): Matched joint type (D-lug
Designation of type lettersF(1)(2)-(3)(4)(5)1 F: Safety protective covers2 (1): Terminal category (T-transformer, B-surge arrester)3 (2): Voltage class (10-10KV, 1-1KV)4 (3): Matched joint type (D-lug
Product features:1) Combine with HUBELL`s fuses link and provide transformers, capacitors, cables and circuits with complete fault protection2) Adapt the principle of arching with gases expelled gradu
Product features:1) Combine with HUBELL`s fuses link and provide transformers, capacitors, cables and circuits with complete fault protection2) Adapt the principle of arching with gases expelled gradu
Product features:1) Combine with HUBELL`s fuses link and provide transformers, capacitors, cables and circuits with complete fault protection2) Adapt the principle of arching with gases expelled gradu
Product features:1) Combine with HUBELL`s fuses link and provide transformers, capacitors, cables and circuits with complete fault protection2) Adapt the principle of arching with gases expelled gradu
Product features:1) Combine with HUBELL`s fuses link and provide transformers, capacitors, cables and circuits with complete fault protection2) Adapt the principle of arching with gases expelled gradu
Likewise in category "Other Insulation Materials":