Russian German French    |    help
   Add to favorite    Favorite products
   
Description
Repair & Construction /  Insulation & Glues /  Other Insulation Materials / 
Producer information
Company:
Zhejiang Zhongyi Electric Power Technology Co., Ltd.
 
Address:
Lutoushi Village,Xiangyang Town, Yueqing, Zhejiang, China (Mainland) Zip: 325619
 
Phone:
+86-577-62602220

Outdoor High-Voltage Isolating Switch


Use conditions:1) The altitude above sea level does not surpass 3,000m2) Surrounding air temperature:a) Upper limit: +40°Cb) Lower limit general area: -30°Cc) High and cold area: -40°C3) The wind pressure does not surpass 700Pa (equal to wind speed 34m/s)4) The earthquake intensity does not surpass 85) Not frequent fierce vibration place6) The ordinary installment place should the not serious influence isolator insulation and the electric conduction ability gas, the vapor, the chemical properties deposition, the salt mist, the dust and other explosive, corrosive matter7) Antifouling is suitable for the heavy contamination area, but should not have causes of the fire and the explosiveSpecifications:Type: HGW9-101) Rated voltage: 12KV2) Rated current: 400A, 630A3) 4S heat steady current: 12.5KA4) Motion steady current: 31.5KA5) Impulse withstand voltage:a) To earth: 75KVb) Across the isolating distance: 85KV6) Power-frequency withstand voltage:a) To earth: 38KVb) Across the isolating distance: 42KVType: HJDW2-0.5KV1) Rated voltage: 0.5KV2) Rated current: 800A, 1000A3) 4S heat steady current: 1250KA4) Motion steady current: 3150KA5) Impulse withstand voltage:a) To earth: 4KVb) Across the isolating distance: 5KV6) Power-frequency withstand voltage:a) To earth: 2KVb) Across the isolating distance: 3KVType: HGW4-35D/630-31.51) Rated voltage: 35KV2) Rated current: 400A, 600A, 1000A3) Mechanical life: ≥2000 times4) Quiet pull: Fa2=800N Fb2=200N5) Operate moment: 300Nm6) Isolating switch rated peak withstand current: 80KA7) Isolating switch rated short-time withstand current: 31.5KA(4S)8) Ground switch rated peak withstand current: 50KA, 80KA9) Ground switch rated short-time withstand current: 20KA(4S), 31.5KA(4S)

Add to BasketAdd to Basket Web addressWeb address



Other goods of this manufacturer :
Outdoor High-Voltage Isolating Switch
 Outdoor High-Voltage Isolating Switch ( Outdoor High-Voltage Isolating Switch)
Use conditions:1) The altitude above sea level does not surpass 3,000m2) Surrounding air temperature:a) Upper limit: +40°Cb) Lower limit general area: -30°Cc) High and cold area: -40°C3
Outdoor Vacuum Circuit Breaker
 Outdoor Vacuum Circuit Breaker ( Outdoor Vacuum Circuit Breaker)
Product Name: Outdoor Vacuum Circuit BreakerModel Number: ZW32-12Place of Origin: ChinaFeatures:1) ZW32-12 series pillar type outdoor vacuum breaker is a kind of outdoor high voltageswitch equipment w
Outdoor Vacuum Circuit Breaker
 Outdoor Vacuum Circuit Breaker ( Outdoor Vacuum Circuit Breaker)
Features:1) ZW8-12, ZW8-12G series high-voltage vacuum circuit breaker is a kind of outdoor high-voltage switch equipment with 50Hz three-phase alternating current and 12kV rated voltage2) It is mainl
Composite Cross-Arm & Post Insulator
 Composite Cross-Arm & Post Insulator ( Composite Cross-Arm & Post Insulator)
Features:1) Manufactured by means of injection whole-molding technology2) The juncture between end fitting and core is totally embedded in HTV silicone rubber, eliminating conventional and traditional
Composite Cross-Arm & Post Insulator
 Composite Cross-Arm & Post Insulator ( Composite Cross-Arm & Post Insulator)
Features:1) Manufactured by means of injection whole-molding technology2) The juncture between end fitting and core is totally embedded in HTV silicone rubber, eliminating conventional and traditional
Composite Dry Type Wall Bushing Insulator
 Composite Dry Type Wall Bushing Insulator ( Composite Dry Type Wall Bushing Insulator)
Features:1) Manufactured by means of injection whole-molding technology2) The juncture between end fitting and core is totally embedded in HTV silicone rubber, eliminating conventional and traditional
Composite Dry Type Wall Bushing Insulator
 Composite Dry Type Wall Bushing Insulator ( Composite Dry Type Wall Bushing Insulator)
Features:1) Manufactured by means of injection whole-molding technology2) The juncture between end fitting and core is totally embedded in HTV silicone rubber, eliminating conventional and traditional
Composite Insulator
 Composite Insulator ( Composite Insulator)
1) Composite post Insulator GW9-10KV2) Composite Post Insulator RW5-35KV3) Drop-out Fuse Insulator RWL-10KV4) Railway Composite Post Insulator FZST-27KV
Composite Insulator
 Composite Insulator ( Composite Insulator)
1) Composite post Insulator GW9-10KV2) Composite Post Insulator RW5-35KV3) Drop-out Fuse Insulator RWL-10KV4) Railway Composite Post Insulator FZST-27KV

Likewise in category "Other Insulation Materials":
 FRP Bench
FRP Bench
 Mechanical Equipment Casing
Mechanica...
 FRP Scoop
FRP Scoop
 Cable Jacket
Cable Jac...
 FRP SMC Box
FRP SMC B...
 Gratings
Gratings
 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com