High Voltage Pin Insulator


Leakage distance: 120mmMinimum breaking load: 1,250kgOne minute withstand-voltage wet: 10kVWeight: 0.4kg

Add to BasketAdd to Basket Web addressWeb address



Other goods of this manufacturer :
High Voltage Pin Insulator E-80
 High Voltage Pin Insulator E-80 ( High Voltage Pin Insulator E-80)
Leakage distance: 120mmMinimum breaking load: 1,250kgOne minute withstand-voltage wet: 10kVWeight: 0.4kg
High Voltage Pin Insulator E95/2
 High Voltage Pin Insulator E95/2 ( High Voltage Pin Insulator E95/2)
Leakage distance: 130 + 30mmMinimum breaking load: 1,250kgOne minute withstand-voltage wet: 10kVWeight: 0.625kg
High Voltage Pin Insulator E95/2
 High Voltage Pin Insulator E95/2 ( High Voltage Pin Insulator E95/2)
Leakage distance: 130 + 30mmMinimum breaking load: 1,250kgOne minute withstand-voltage wet: 10kVWeight: 0.625kg
Line Post Insulator
 Line Post Insulator ( Line Post Insulator)
Leakage distance: 737mmDry arcing distance: 311mmCantilever strength: 12.5kNAverage flashover voltage, low-frequency: dry 125kV, wet 100kVAverage flashover voltage, critical-impulse: positive 210kV, n
Line Post Insulator
 Line Post Insulator ( Line Post Insulator)
Leakage distance: 559mmDry arcing distance: 241mmCantilever strength: 12.5kNAverage flashover voltage, low-frequency: dry 110kV, wet 85kVAverage flashover voltage, critical-impulse: positive 180kV, ne
Line Post Insulator ANSI57-2
 Line Post Insulator ANSI57-2 ( Line Post Insulator ANSI57-2)
Leakage distance: 559mmDry arcing distance: 241mmCantilever strength: 12.5kNAverage flashover voltage, low-frequency: dry 110kV, wet 85kVAverage flashover voltage, critical-impulse: positive 180kV, ne
Line Post Insulator ANSI57-3
 Line Post Insulator ANSI57-3 ( Line Post Insulator ANSI57-3)
Leakage distance: 737mmDry arcing distance: 311mmCantilever strength: 12.5kNAverage flashover voltage, low-frequency: dry 125kV, wet 100kVAverage flashover voltage, critical-impulse: positive 210kV, n
Metal Oxide Arrester for AC System
 Metal Oxide Arrester for AC System ( Metal Oxide Arrester for AC System)
System voltage (rms): 35kVRated voltage (rms): 51kVPower frequency sparkover voltage not less than (rms): 82kVMax. impulse sparkover voltage at 1.2/50μs not more than: 134kV (peak)Residual (peak
Pin Type High Voltage Insulator
 Pin Type High Voltage Insulator ( Pin Type High Voltage Insulator)
Glaze: plainMin. pin height: 5"Leakage distance: 9"Dry arcing distance: 5"Low frequency voltage: dry flashover 70kV, wet flashover 40kV, puncture 95kVCritical-impulse flashover voltage: positive 110kV