English Russe Französische    |    Hilfe
   Zu Favoriten     Dem Warenkorb hinzugefügte Favoriten
   
Beschreibung der Ware
Büromaterial /  Sicherheitssystemausrüstung /  Feuersignalsysteme / 
Informationen über den produzenten
Firma:
Vedard Security & Fire Alarm Technology
 
Adresse:
Qingmeng industrial zone
 
Telefon:
+86-180-50996636

.

This fire alarm control panel meets NFPA requirement. It should be installed, commissioned and maintained by suitably qualified service personnel. 1. It has 16 zones and 4 sounder outputs. 2. It has 3 standard FORM-A relays contact for alarm, fault, supervisory. And it has EIA-485 port for communication with remote delay and repeater panel. 3. It works with conventional N/O contact input devices including 2 wire, 4 wire smoke detector, heat detector, gas detector and call points etc. 4. It can be programmed by panel keypad. It is supervised all wiring, AC voltage and battery level. 5. It is required to be connected to power earth and it self checks earth fault. 6. Max.20 detectors can be equipped in one zone. Each zone can be disabled separately. 7. Output circuits: 24V resettable power output 1000mA 24V Nonresettable power output 1000mA 24V battery charger (up to 18AH battery) 8. EIA-485 port (interfaces to Annunciators, Graphic Annunciators and Remote Relay module) 9. 75VA power module is provided with the panel 10. Sound 1-4 output can be manual activate directly or disabled. 11. Panel running mode can be switched to manual or automatic. 12. It reports short and broken circuit of zones. 13. It is designed with space of 2 pcs sealed lead-acid backup battery. 14. It is with Test and disable function. 15. It can connect with Max.32 repeater panels by RS485 port.Shop it at http://www.vedardalarm.com/conventional-fire-alarm-systems-c-11 Specification: 1. Power supply:AC90~270VAC 50Hz 3A 2. Wire size: Minimum #14 AWG (2.0mm²) with 600V insulation. 3. Detector loop current is sufficient to ensure operation of 2 alarmed detectors per zone. Standby current: 7.26mA 4. Three relay output relay contact rating: 2A at 30VDC 5. Total DC current output: 500mA 6. Recommend Max. standby current: 150mA 7. Input circuits 1-16 zones may be used as standard fire alarm control panel zones and accpet N/O contact devices. 8. Output circuits 24V resettable power output 1000mA 24V Nonresettable power output 1000mA 24V battery charger (up to 18AH battery) EIA-485 port 9. Dimension: 35cm*40cm*16.5cm It is with space of 7AH backup battery
In den WarenkorbIn den Warenkorb Internetauftritt des HerstellersInternetauftritt des Herstellers




Andere Waren dieses Produzenten :
 ()
SB-116 Manual call point 2-wire The conventional manual call point is designed for fire alarm systems and security alarm systems It is with pull down plate for safe and easy press to call at emergency
 ()
Conventional photoelectric smoke alarm 24V 2 wire EN54 Certificated 2 wire conventional photoelectric smoke sensor The fire detector should be tested and maintained regularly following NFPA 72 require
 ()
T001Q3 is solar power wireless perimeter beams for balcony, wall, window, fence security. It works as infrared light wall to prevent illegal invasion from wall, window, fence, garden etc. perimeter pr
 ()
Siren Strobe alarm bell is Fire alarm or intruder alarm sounder and lighter to notice neighbor and police. It is wire or wireless connect to alarm signal center for guard room. The sound is lound at 1
 ()
Smoke detector or smoke alarm is important part of fire signal system.620DH is DC power Smoke detector photoelectric sensor. It can add heat sensor into one to have compound Smoke and Heat Detector.&n
 ()
ST-IVB is newest technology wireless alarm control panel. It can be used for home security, office security, small business security. It is with GSM and PSTN double network for SMS and voice ccalling
 ()
EAVS is high integrated security alarm server. EAVS means Explorer + Alarm + Video +Server. It integrates Alarm and NVR and IE explorerIt adopts updated technology Video processing in CPU and DSP hard
 ()
Innovative LoRa reliable wireless fire alarm complete automatical fire fighting fire prevention security system. Shop professional newest technology fire alarm systems online at fire alarmThe wireles
 ()
MD-210R is smart door wireless contact with door open alarm immediately. It will report door open status to alarm panel. It is battery powered wireless magnetic door open contact with wired to wireles

Òàê æå â êàòåãîðèè "Feuersignalsysteme":
Smoke Detector
Smoke Dete...
ELECTRONIC DUAL SIREN for house system
ELECTRONIC...
TK-428 Twin Piezo Siren
TK-428 Twi...
TK-438 Twin Piezo Siren + Flasher
TK-438 Twi...
Siren (AR165)
Siren (AR1...
Foam Head.
Foam Head.
 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com