English Russe Französische    |    Hilfe
   Zu Favoriten     Dem Warenkorb hinzugefügte Favoriten
   
Beschreibung der Ware
Medizinisch & Arzneimittel /  Medizinische Ausrüstung /  Diagnostische Ausrüstung / 
Informationen über den produzenten
Firma:
Getein Biotechnology Co., Ltd.
 
Adresse:
No.9 Bofu Road,Luhe District,Nanjing,211505,China
 
Telefon:
+86-25-68576663

.

 Intended Use:  One Step Test for CK-MB/cTnI/Myo(Colloidal  Gold)applies colloidal gold immunochromatography  to detect CK-MB/cTnI/Myo in serum and plasma samples semi-quantitatively or quantitatively.  Principle of the Procedure:  Two kinds of high specific and sensitive CK-MB/cTnI/Myo monoclonal antibodies are used for the test strips. One is gold-labelled and coated on the polyester film, and the other is fixed on the test lines. The antibodieson the test lines form sandwich complexes with any CKMB/cTnI/Myo in the blood sample.The sample passes through the detection zone, in which the sandwich complexes gather along a line, appearing as a purplish red streak (the test or signal line). Excess gold-labelled antibodies gather along the control line, signaling visually that the test is valid. The intensity of the test line increases in proportion to the CK-MB/cTnI/Myo concentration.  Test Procedure: 1. Restore the test card and the blood specimen to room temperature (20~25°C better).2. Open the pouch and label the strip with the patient specimen number.3. Use the pipette to transfer blood from a sample collection tube.4. Release the bulb slowly, dropping 3 to 4 drops (or 120 μl) of the sample.5. Referring to standard colorimetric card, get the semi-quantitative result by eye or read the quantitative result with the matching equipment. The result must be read within 10~30 mins.  Warnings and Precautions:  1. Use for in vitro diagnostics. 2. Use by healthcare professionals. 3. The best testing temperature is 15~30 C, and the best humidity is 40~60%. 4. Do not use the stri p beyond the expiration date pri nted on the outside of the box. 5. The stri p must be used within 1 hour once its foil pouch has been opened. 6. The transfer pipette shoul d be used for one specimen only. Discard it after used. 7. Patient specimens, used strip and transfer pipettes may be potentially infectious. Proper handling and disposal methods should be established by the laboratory direction in accordance with local regulations. 8. Proper laboratory safety  techniques should  be followed  at all  times  when  working  with potentially infectious blood specimens.  
In den WarenkorbIn den Warenkorb Internetauftritt des HerstellersInternetauftritt des Herstellers




Andere Waren dieses Produzenten :
 ()
Usages of medical x-ray fluoroscopy machine for sale  PLD7200AThis digital radiographic machine is available for medical teaching, research, medical units for X-ray spot film gastrointestinal pho
 ()
1. The image is clearer for using high quality combined HF HV X-ray generator, high performance image intensifier and high-resolution, high definition CCD.2. With functions of electric up and down mov
 ()
Features  of Remote Controlled Diagnostic X-ray Machine PLX22001. The image is clearer for using high quality combined HF HV X-ray generator, high performance image intensifier and high-resolutio
 ()
Usage of ventilatorS1600  is  the type of electrically and pneumatically controlled synchronous respirator with time switch. It is mainly used for the saving of patients with respiratory fai
 ()
Usage  of biochemistry analyzer with cheap price PUS-2018N  The biochemistry analyzer equipment  is a high performance photometer and  can be used in  clinics of hospitals,epi
 ()
Usage  of clinical biochemical analyzer  The biochemistry analyzer equipment  is a high performance photometer and  can be used in  clinics of hospitals,epidemic prevention st
 ()
As discussed below, we have lanched in unique design high-end PLX8500F 500μ Type DR X-rays.This NEW DESIGNED 0.5ms ultrashort exposure?1000mA High Frequency FPD DR System(PLX8500F) has below featur
 ()
Adapt to: Suitable for adult child and baby (no fetus). Can work in ICU, operation room, ward, ambulance.(Patient Monitor For Hospital JP2000-09)Elemental functions: Can monitor the patient sign of EC
 ()
Specifications of Mobile x ray Bed for C-arm PLXF1531.X Ray Compatible Operation Room Bed 2.surgical x ray table 3. medical x ray machine  Application of simple surgical bed for C-

Òàê æå â êàòåãîðèè "Diagnostische Ausrüstung":
Thermometers
Thermomete...
Digital Blood Pressure Monitor
Digital Bl...
Digital Blood Pressure Monitor
Digital Bl...
Sphygmomanometers/blood pressure monitors
Sphygmoman...
EAR THERMOMETER
EAR THERMO...
Body fat monitor
Body fat m...
 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com